Multiple Installations; Technical Data & Dimension Sheets - Spartherm XS 500 Installation And Operating Instructions Manual

Linear fireplace cassettes
Table of Contents

Advertisement

and the airflow volume of the ventilation systems do not cause low pres-
sure less than 0.04 mbar in the installation room used for the open
fireplace and any combined rooms providing ventilation.
Fireplace cassettes may not be installed in:
• Stairwells, except in residential buildings with no more than two
apartments.
• Hallways that are generally accessible
• Garages
• Rooms in which highly flammable or explosive materials or mixtures are
processed, stored or manufactured in such volumes that danger may
result from them exploding or becoming inflamed. Fireplace cassettes
may not be installed in rooms or apartments that are vented using venti-
lation systems or hot air heating systems with the aid of fans, unless the
safe operation of the fireplace cassette is guaranteed.

2.2.2 MULTIPLE INSTALLATIONS

It is possible to have multiple installations connected to a chimney in
accordance with DIN 18160 because the fireplace cassettes are fitted with
a self-closing firebox door (A1). All of the fireplaces connected to a chimney
must also have been approved for multiple installations!
2.3 TECHNICAL DATA & DIMENSION SHEETS
The following information has been taken from the testing report and cor-
responds to the testing conditions!
Fireplace
XS 500
cassette
Technical
Unit
D4
E4
data:
Type of fuel:
-
Room thermal
kW*
4,0
4,6
output:
Wood feed
kg/h
~ 1,2 ~1,4
quantity:
4,0-
4,5-
Thermal output:
kW
5,2
6,0
Efficiency:
%*
CO-emissions at
mg/Nm³
13% O
:
2
Dust emissions:
mg/Nm³
Exhaust gas
temperature at
°C
252
sockets:
Manometric
Pa
pressure:
Exhaust gas
g/s
3,8
mass flow:
Combustion air
m³/h
12,6
requirement
Weight depend-
kg
50
ing on design
Power supply
-
(only with hot air blower)
Requirements:
1. level of BlmSchV.
2. level of BlmSchV.
EN 13240
DIN Plus
Regensburg
München
Aachen
15a (for Austria)
Clean Air Ordinance from
01.2011 (for Switzerland)
* The values given represent the average recorded from multiple fires. These values were recorded under test
conditions without the hot air blower being switched on.
GB 7
S 600
M 700
L 800
XL 900
D5
E5
D6
E7
D8
E10
D11
E 14
Firewood
4,9
4,9
5,9
6,9
7,9
9,9
10,5
14,0
~1,5
~1,5
~1,8 ~2,1 ~2,4
~3,0
~3,2
~4,2
4,0-
4,0-
4,5-
4,8-
5,5-
6,9-
7,4-
9,8-
6,4
6,4
7,7
9
10,3
12,9
13,7
15
> 80
> 79
> 78
< 1250
< 40
335
335
370
360
340
330
360
12
4,5
5,0
6,5
9,0
10,0
12,0
15,5
16,2 16,6
20,2
26,4
34,3
40,3
80
95
110
130
230V 50 HZ AC