5. PARAMETERS
(2) Details list
Classifi-
No.
Symbol
cation
1
*AMS
Amplifier setting
Used to select the absolute position detection.
2
*REG
Regenerative brake resistor
Used to select the regenerative brake option used.
3
For automatic setting by servo system controller
Automatically set from the servo system controller
4
5
Name and Function
0
0
0
Absolute position detection selection
0: Invalid (Used in incremental system.)
1: Valid (Used in absolute position
0 0
Regenerative selection brake option
00: Regenerative brake option is not used with
7kW or less servo amplifier (The built-in
regenerative brake resistor is used. However,
the MR-J2S-10B does not have a built-in
regenerative brake resistor and therefore
cannot use it.)
Supplied regenerative brake resistors or
regenerative brake option is used with 11kW
or more servo amplifier
01: FR-RC, FR-BU, FR-CV
05: MR-RB32
08: MR-RB30
09: MR-RB50
0B: MR-RB31
0C: MR-RB51
0E: When regenerative brake resistors or regenerative
brake option supplied to 11kW or more are cooled
by fans to increase capability
10: MR-RB032
11: MR-RB12
The MR-RB65, 66 and 67 are regenerative brake
options that have encased the GRZG400-2 ,
GRZG400-1 and GRZG400-0.8 , respectively.
When using any of these regenerative brake
options, make the same parameter setting as
when using the GRZG400-2 , GRZG400-1 or
GRZG400-0.8
resistors or regenerative brake option is used
with 11kW or more servo amplifier).
Select the external dynamic brake.
0: Invalid
1: Valid
Select "1" when using the external dynamic
brake with the MR-J2S-11KB or more.
POINT
Wrong setting may cause the regenerative brake option to burn.
If the regenerative brake option selected is not for use with the
servo amplifier, parameter error (37) occurs.
detection system.)
(supplied regenerative brake
5 - 4
Initial
Setting
Unit
Value
Range
0000
Refer to
name
and
function
column.
0000
Refer to
name
and
function
column.
0080
0000
1

Hide quick links: