Mitsubishi Electric MR-J2S-*B Series Instruction Manual page 194

General-purpose ac servo. sscnet compatible. servo amplifier
Table of Contents

Advertisement

12. OPTIONS AND AUXILIARY EQUIPMENT
(5) Specifications
Power regeneration common converter
Item
Total of connectable servo amplifier capacities
Maximum servo amplifier capacity
Total of connectable servo motor rated
currents
Output
Regenerative
braking torque
Rated input AC voltage/frequency
Permissible AC voltage fluctuation
Power supply
Permissible frequency fluctuation
Power supply capacity (Note 2) [kVA]
Protective structure (JEM 1030), cooling system
Ambient temperature
Environment
Ambient humidity
Ambience
Altitude, vibration
No-fuse breaker or leakage current breaker
Magnetic contactor
Note1. This is the time when the protective function of the FR-CV is activated. The protective function of the servo amplifier is
activated in the time indicated in Section 11.1.
2. When connecting the capacity of connectable servo amplifier, specify the value of servo amplifier.
7.5K
FR-CV-
[kW]
3.75
[kW]
3.5
33
[A]
Short-time
Total capacity of applicable servo motors, 300% torque, 60s (Note)
rating
Continuous
rating
17
Indoors (without corrosive gas, flammable gas, oil mist, dust and dirt)
1000m or less above sea level, 5.9m/s
30AF
30A
S-N20
12 - 37
11K
15K
22K
5.5
7.5
11
5
7
11
46
61
90
100% torque
Three-phase 200 to 220V 50Hz, 200 to 230V 60Hz
Three-phase 170 to 242V 50Hz, 170 to 253V 60Hz
5%
20
28
41
Open type (IP00), forced cooling
-10
to +50
(non-freezing)
90%RH or less (non-condensing)
2
50AF
100AF
100AF
50A
75A
100A
S-N35
S-N50
S-N65
30K
37K
15
18.5
15
15
115
145
52
66
or less (compliant with JIS C 0040)
225AF
225AF
125A
125A
S-N95
S-N95
55K
27.5
22
215
100
225AF
175A
S-N125

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents