Resetting the Controller

There are four reset modes (numbered 1, 3, 4, and 5 for the sake of comparison with other
Extron IPL products) available by using the
page) on the front panel. The
pen, or Extron Tweeker is suggested.
ATTENTION:
Mode Activation
1
Hold down the recessed
button while applying power to
the IPL T CR48.
After a mode 1
NOTE:
reset is performed, update
the firmware of the unit to
the latest version. Do not
operate the IPL T CR48
firmware version that
results from the mode
1 reset. This mode
temporarily resets the
unit to factory default until
power is recycled. If you
want to use the factory
default firmware, you must
upload that version again.
3
Hold down the
Reset
about 3 seconds until the Power
LED blinks once, then release
and press
momentarily
Reset
(<1 second) within 1 second*.
Reset
Review the reset modes carefully. Using the wrong reset mode may result in
unintended loss of blink memory programming, port reassignment, or processor
reboot.
Analysez minutieusement les différents modes de réinitialisation.
mode de réinitialisation peut causer une perte inattendue de la programmation de la mémoire
blink, une reconfiguration des ports ou une réinitialisation du processeur.
IPL T CR48 Reset Mode Summary
Result
The IPL T CR48 reverts to the
Reset
factory default firmware.
Event scripting does not start
if the unit is powered on in this
mode. All user files and settings
(such as drivers, adjustments,
and IP settings) are maintained.
If you do not want
NOTE:
to update firmware, or you
performed a mode 1 reset
by mistake, cycle power
to the unit to return to the
firmware version that was
running prior to the mode
1 reset. Use the 0Q SIS
command to confirm that
the factory default firmware
is no longer running (look
for asterisks following the
version number).
button for
Mode 3 turns events on or off.
If the events are currently
stopped following the momentary
press, the power LED blinks
twice, indicating the starting of
events. If the events are currently
running following the momentary
press, the Power LED blinks
three times indicating the
stopping of events.
button (see
figure 8,
Reset
button is recessed, so use of a pointed stylus, ballpoint
Purpose and Notes
Use mode 1 to revert to
the factory default version if
incompatibility issues arise with
user-loaded firmware.
NOTE:
pages may not work
correctly if using an earlier
firmware version.
Mode 3 is useful for
troubleshooting.
IPL T CR48 • Installation and Operation