IBM System/36 Maintenance Information Manual page 95

System unit
Hide thumbs Also See for System/36:
Table of Contents

Advertisement

Setup Procedure
1. Set the scope switches as follows:
CH 1 VOLTS/DIV: 0.5 volts
AC-GND-DC: AC
INVERT: Inverted (out)
VERT MODE: CH 1
A and B TIME/DIV
and DELAY Time:
Set A to 10 microseconds,
pull knob to unlock, and
set B to 2 microseconds.
HORIZ DISPLAY: B DL Y'D
TRIG MODE: AUTO
COUPLING: AC
SOURCE: STARTS AFTER DELAY
SLOPE: Minus
2. Attach the T -connector
II
to B
+
GATE on the rear panel of the oscilloscope.
3. Use the probe tip adapter
II
(part 453199) to attach the channell probe to one side of the T-connector.
4. Attach the probe
II
(part 1650290) to the other side of the T-connector.
5. If you are checking an IBM Cabling System, go to step 7. For twinaxial cables, continue with step 6.
Attach to B
+
Gate
on Rear Panel of
Oscilloscope
CH 1
Input
T-Connector
(part 1650789)
Probe
(part 1650790)
Probe Tip Adapter
(part 453199)
Ground Lead
R36B117·0
Section 7. Local Work Station Procedures
7-5