440 Base and Feature DC Voltage Tolerances
The base and feature DC voltages can be measured at the connector pins shown in section 435.
Voltage
Minimum
Maximum
+ 1.7 volts
+ 1.66
+ 1.73
+ 5 volts
+4.80
+5.25
-5 volts
-4.60
-5.50
+ 12 volts
+ 11.20
+ 12.60
See note.
-12 volts
-10.90
-13.20
Note: The + 12 volts tolerances measured at P4 and P11
are minimum of + 11.52 volts and maximum of
+ 12.60 volts.
445 Maximum Ripple Voltage
The ripple voltage can be measured at the connector pins shown in the following tables:
A1 Board
Probe
Ground
Connector
Pin
Connector
Pin
Maximum Ripple
PI
1
P2
1
200 millivolts
PI
2
P2
1
200 millivolts
PI
4
P2
1
200 millivolts
P2
4
P2
1
200 millivolts
P2
5
P2
2
200 millivolts
P2
6
P2
3
200 millivolts
P3
1
P3
6
30 millivolts
P3
2
P3
7
30 millivolts
P3
3
P3
8
30 millivolts
Section 4. Power Procedures
4-13