Aprilia Consumer Service Spa
Technical Service and Training
Release 4 july 99
DIODE MODULE:
The figure shows the electrical wiring in the module. The continuity of the diodes can be checked with a tester
or with a 4.5 - 12 Volt battery with an arbitrary load of max. 2 Watts.
Remember that the diode conducts the current one way only, as indicated by the arrow representing the
component in the diagram.
This material is didactic and
may be changed following the technical
development of the product