Description
parameter
WP058
Enable function for active cooling.
WP061
Sets night mode end time (WP061 must be less than WP062)
WP062
Sets night mode start time (WP061 must be less than WP062)
WP064
Limits maximum possible compressor frequency and fan speed during night mode.
WP066
Night mode
Used to enable/disable limitation of the maximum possible fan speed and compressor frequency
values within the set duration of night mode.
Enabling night mode results in a reduction of the maximum potential heating output/cooling capacity
of the appliance.
WP080
Dual mode point for deactivation of the compressor.
WP090
Enables the electric heater for heating mode.
WP091
Dual mode point for activation of the electric heater for heating mode
WP092
For setting power-OFF for the electric heater.
WP093
Deactivation of the dual mode point (WP091) of the electric heater for the set period. Used during
the screed drying function to ensure that the electric heater supports the heat pump.
WP094
Sets existing electric heater or
currently installed connected load of electric heater.
WP101
Dual mode point for activation of additional heat generator for heating mode.
WP104
Additional heat generator activation via eBUS.
WP121
Serves to limit the compressor start-ups per hour.