Wolf BWL-1S-05 Installation And Operating Instructions Manual page 113

Split air/water heat pump
Hide thumbs Also See for BWL-1S-05:
Table of Contents

Advertisement

Type
Air/water heat pump
Water/water heat pump
Brine/water heat pump
Low temperature heat pump
With booster heater
Combi boiler with heat pump
Information
Symbol
Rated heating output (*)
Specified output for partial load
at 20 °C room air temperature
and outdoor air temperature
Tj = -7 °C
Tj = +2 °C
Tj = +7 °C
Tj = +12 °C
Tj = dual mode temperature
Tj = operating temperature limit
For air/water heat pump Tj =
-15 °C (where TOL < -20 °C)
Dual mode temperature
Seasonal central heating
efficiency
Specified coefficient of
performance or primary energy
ratio for partial load at 20 °C
room temperature and outdoor
air temperature
Tj = -7 °C
Tj = +2 °C
Tj = +7 °C
Tj = +12 °C
Tj = dual mode temperature
Tj = operating temperature limit
For air/water heat pump Tj =
-15 °C (where TOL < -20 °C)
For air/water heat pump:
Operating temperature limit
Heating water operating
temperature limit
Power consumption in operating
modes other than the operating
condition: OFF state
Power consumption in operating
modes other than the operating
condition: Thermostat OFF state
Power consumption in operating
modes other than the operating
condition: Standby mode
Power consumption in operating
modes other than the operating
condition: Crankcase heater mode
Booster heater rated heating
output
Energy supply type
Output control
Indoor sound power level
Outdoor sound power level
For air/water heat pump: Nominal
air flow rate, outdoors
For water/brine-water heat pump:
Nominal water or brine flow rate
Contact
3021351 06/2017
3064298_201805
Technical parameters
Technical p arameters t o E U R egulation N o. 8 13/2013
to EU Regulation No. 813/2013
BWL-1SB-10/230 V BWL-1SB-14/230 V
(Yes/No)
Yes
Yes
(Yes/No)
No
No
(Yes/No)
No
No
(Yes/No)
No
Yes
(Yes/No)
Yes/No
Yes/No
(Yes/No)
No
No
Values for medium temperature (55 °C)/
low temperature (35 °C) application with
average climate conditions
Unit
55 °C
35 °C
P
kW
10
10
rated
Pdh
kW
8.0
9.0
Pdh
kW
5.1
5.5
Pdh
kW
4.6
4.8
Pdh
kW
5.6
5.8
Pdh
kW
7.8
7.9
Pdh
kW
6.8
9.1
Pdh
kW
-
-
T
°C
-5
-5
biv
n
%
111
150
s
COPd
-
1.64
2.52
COPd
-
2.89
3.63
COPd
-
4.10
5.34
COPd
-
5.23
7.32
COPd
-
1.85
2.84
COPd
-
1.38
2.10
COPd
-
-
-
TOL
°C
-10
-10
WTOL
°C
55
55
P
kW
0.026
0.026
OFF
P
kW
0.026
0.026
TO
P
kW
0.026
0.026
SB
P
kW
0.000
0.000
CK
P
kW
2.84 / 0.0 0.7 / 0.0 4.61 / 0.0 2.9 / 0.0
sup
-
-
electrical
fixed/variable
variable
L
dB
42
42
WA
L
dB
63
63
WA
-
m3/h
3800
3800
-
m3/h
-
-
WOLF GmbH, Industriestrasse 1, 84048
Mainburg, Germany
Yes
Yes
No
No
No
No
No
Yes
Yes/No
Yes/No
No
No
55 °C
35 °C
11
12
7.9
9.8
6.8
6.7
4.7
4.9
5.5
5.2
8.3
8.9
6.8
8.7
-
-
-3
-4
111
150
1.61
2.23
3.01
3.93
4.29
5.51
4.95
5.27
2.01
2.82
1.38
2.04
-
-
-10
-10
55
55
0.026
0.026
0.026
0.026
0.026
0.026
0.000
0.000
electrical
variable
44
44
63
63
3800
3800
-
-
113