Scalance X101-1Aui Aui Interface - Siemens SCALANCE X101-1AUI Commissioning Manual

Simatic net industrial ethernet
Table of Contents

Advertisement

MDI /MDIX Autocrossover Function
The advantage of the MDI /MDIX autocrossover function is that straight-through cables can
be used throughout and crossover Ethernet cables are unnecessary. This prevents
malfunctions resulting from mismatching send and receive wires. This makes installation
much easier for the user.
All devices of the SCALANCE X-101 product line support the MDI / MDIX autocrossover
function.
Note
Autopolarity is not supported.
3.6

SCALANCE X101-1AUI AUI Interface

Transmission Rate
The transmission rate is 10 Mbps.
Transmission Mode
The AUI transmission mode is specified in the IEEE 802.3 standard.
Since half duplex mode and the transmission rate of 10Mbps are specified, autonegotiation
cannot be selected on the TP port.
Transmission Medium
AUI cable (drop cable / EFB Ethernet transceiver cable)
Range
The maximum transmission range (segment length) is 50 m.
Medium Attachment Unit – Supply
At 12 V, maximally 500 mA are provided to a Medium Attachment Unit.
Connectors
Interlocking 15-pin SUB-D connectors are used for the connection.
Industrial Ethernet Media Converters SCALANCE X-100 Series
Commissioning Manual, 06/2006, A2B00051526A, Product Version 03
Product Characteristics
3.6 SCALANCE X101-1AUI AUI Interface
3-5