Uninstalling
To remove SCALANCE X101-1AUI from the rail:
1. First disconnect the TP cable and the AUI cables. Remove the terminal block for the
2. Use a screwdriver to release the lower rail catch of the device and pull the lower part of
Figure 4-2
Industrial Ethernet Media Converters SCALANCE X-100 Series
Commissioning Manual, 06/2006, A2B00051526A, Product Version 03
power supply and the signaling contact.
the device away from the rail.
Removing from a DIN rail (35 mm)
Installation and Maintenance
4.1 Installation
4-3