Junction Terminal Block Mr-Tb50 [A] - Mitsubishi Electric MR-J5 Series User Manual

Ac servo system
Hide thumbs Also See for MR-J5 Series:
Table of Contents

Advertisement

6.5

Junction terminal block MR-TB50 [A]

Usage
Always use the junction terminal block (MR-TB50) with the junction terminal block cable (MR-J2M-CN1TBL_M) as a set.
Servo amplifier
CN1
Junction terminal block cable
(MR-J2M-CN1TBL_M)
Ground the junction terminal block cable on the junction terminal block side with the supplied cable clamp fitting (AERSBAN-
ESET). For the use of the cable clamp fitting, refer to the following.
Page 182 Cable clamp fitting AERSBAN-_SET
Terminal block label
Use the following for the junction terminal block. The label is supplied with the junction terminal block MR-TB50.
Position control mode
P15R LG
LAR LBR LZR
PG
SON
LA
LB
LZ
PP
OPC
Speed control mode
P15R LG
LAR LBR LZR
SON
VC
LA
LB
LZ
Torque control mode
P15R LG
LAR LBR LZR
SON
VLA
LA
LB
LZ
Dimensions
2
1
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32
Junction terminal block
MR-TB50
Cable clamp
PC
RES
ZSP TLC TLA
DICOM
TL
INP
INP
LG
LG
DICOM
ST1 RES
ZSP TLC TLA
DICOM
SP2
ST2
SA
SA
LG
LG
DICOM
SR2 RES
ZSP VLC
TC
DICOM
SP2
RS1
LG
LG
DICOM
235
50
49
MITSUBISHI
MR-TB50
35 37 39 41 43 45 47 49
34 36 38 40 42 44 46 48 50
244
OP
NP
CR
LSP LOP
DOCOM
LG
NG
EMG LSN
ALM
DOCOM
OP
SP1 LSP LOP
DOCOM
LG
EMG LSN
ALM
DOCOM
OP
SP1
LOP
DOCOM
LG
EMG
ALM
DOCOM
[Unit: mm]
2-φ4.5
Terminal screw: M3.5
Applicable wire: 2 mm
Crimp terminal width: 7.2 mm or less
6 OPTIONS AND PERIPHERAL EQUIPMENT
6.5 Junction terminal block MR-TB50 [A]
RD
SD
RD
SD
RD
SD
46.5
2
6
161

Advertisement

Table of Contents
loading

Table of Contents