Red (Redundancy Mode); Rem (Remote Mode); Ret (Retrieve Equipment Type) - Comtech EF Data MN/LBC4000.IOM Installation And Operation Manual

L-band up/down converter system
Table of Contents

Advertisement

LBC-4000 L-Band Up/Down Converter System
Serial Interface Operation

8.3.27 RED (Redundancy Mode)

Command or query. Use "RED" to set or return the active redundancy mode.
Controller-to-Target
Arguments for
Instruction Code and Qualifier
Command or
Response to
Command
Query
RED_
RED_
3 bytes,
alphabetic

8.3.28 REM (Remote Mode)

Command or Query. Use "REM" to set or return the active operating mode as
Local or Remote.
Controller-to-Target
Arguments for
Instruction Code and Qualifier
Command or
Response to
Command
Query
REM_
REM_
1 bytes,
numeric, 0 or 1
Command Example: <0001/REM_1{cr} (sets operation to Remote Mode)

8.3.29 RET (Retrieve Equipment Type)

Query only. Use "RET" without an argument to return the model number and
firmware version of the unit.
Controller-to-Target
Arguments for
Instruction Code and Qualifier
Command or
Response to
Command
Query
N/A
RET_
22 bytes,
alphanumeric
Query Example:
Description of Arguments
Query
Set or return in the form RED_yyy where:
yyy=ON (Redundancy is enabled) or OFF
(Redundancy is disabled)
Description of Arguments
Query
Set or return in the form REM_x where:
x=0 (Local Mode) or 1 (Remote Mode)
Description of Arguments
Query
Query, when used without argument, returns a
string in the form RET_LBC-4000_VER:X.X.X
where:
X.X.X=Firmware Version Number
<0001/RET_{cr}
>0001/RET_LBC-4000 VER:1.2.5{cr}{lf}
8–19
MN/LBC4000.IOM
Revision 5
Target-to-Controller
Response
Command
Query
RED_
RED_
Target-to-Controller
Response
Command
Query
REM_
REM_x
Target-to-Controller
Response
Command
Query
N/A
RET_

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lbc-4000Cd-mnlbc4000

Table of Contents