Band-stop with infinite notch depth
Table 3-3
Example of band-stop with infinite notch depth
STARTER filter parameters
f
Blocking frequency
= 500 Hz
Sp
(--3dB) f
Bandwidth
= 500 Hz
BB
K
Notch depth
= --∞ dB
Abs
Reduction
= 0 dB
Simplified conversion to parameters for general order filters:
Reduction or increase after the blocking frequency (Abs)
Infinite notch depth at the blocking frequency
S Numerator frequency f
S Numerator damping 0
S Denominator frequency f
S Denominator damping D
© Siemens AG, 2005. All rights reserved
SINAMICS S120 Function Manual, 06/05 Edition
Amplitude log frequency curve
= f
Z
Sp
= f
N
Sp
f
BB
=
N
2 ⋅ f
Sp
Operating Modes
Servo control
Phase frequency curve
3-81