Supply
Active infeed
Control and status messages
Table 1-2
Active infeed open-loop control
Signal name
ON/OFF1
OFF2
Enable operation
Disable motor operation
Inhibit regenerating
Acknowledge error
Master ctrl by PLC
Table 1-3
Active infeed status message
Signal name
Ready to start
Ready to run
Operation enabled
Fault active
No OFF2 active
Power-up inhibit
Alarm present
Controlled by PLC
Pre-charging compl
Line contactor energized feedback
1-24
Internal
Binector Input
control word
STWAE.0
p0840 ON/OFF2
STWAE.1
p0844 1 OFF2 and
p0845 2 OFF2
STWAE.3
p0852 Enable
operation
STWAE.5
p3532 Disable
motor operation
STWAE.6
p3533 Inhibit
regenerating
STWAE.7
p2103 1
Acknowledge or
p2104 2
Acknowledge or
p2105 3
Acknowledge
STWAE.10
p0854 Master ctrl
by PLC
Internal status
word
ZSWAE.0
ZSWAE.1
ZSWAE.2
ZSWAE.3
ZSWAE.4
ZSWAE.6
ZSWAE.7
ZSWAE.9
ZSWAE.11
ZSWAE.12
Display of
internal control
word
r0898.0
A_STW1.0
r0898.1
A_STW1.1
r0898.3
A_STW1.3
r0898.5
A_STW1.5
r0898.6
A_STW1.6
r2138.7
A_STW1.7
r0898.10
A_STW1.10
Parameter
telegram 370
r0899.0
A_ZSW1.0
r0899.1
A_ZSW1.1
r0899.2
A_ZSW1.2
r2139.3
A_ZSW1.3
r0899.4
A_ZSW1.4
r0899.6
A_ZSW1.6
r2139.7
A_ZSW1.7
r0899.9
A_ZSW1.9
r0899.11
A_ZSW1.11
r0899.12
A_ZSW1.12