5.11  Installing User-Supplied Safety Equipment
WARNING: PERSONAL INJURY RISK
!
To fulfill the "Single Point of Control" requirement, do not place the Manu-
al/Automatic and High Power On controls in multiple locations. After putting
the robot into Manual mode, the operator should remove the key for safety pur-
poses. The system should not be wired so that a PLC or another operator can
put the system back into Automatic mode.

High Power On/Off Lamp

The Front Panel High Power On/Off Lamp (P/N: 27400-29006) will cause an error, from eV+, if
the lamp burns out. This error prevents High Power from being turned on. This safety feature
prevents a user from not realizing that High Power is enabled because the High Power indic-
ator is burned out. See Changing the Lamp in the Front Panel High-Power Indicator on page
186 for information on changing this lamp.

Remote Front Panel or User-Supplied Control Panel Usage

Users can mount the Front Panel remotely by using an extension cable or by wiring a user-sup-
plied Front Panel (control panel) to the controller using the 15-pin XFP connector. The Front
Panel contains no active components, only switches and lights. Customers should be able to
adapt the Front Panel's functionality into their own Front Panel design. To automatically con-
trol the Front Panel's signals, use relay contacts instead of switches. See the figure System
Installation on page 71 for a schematic drawing of the Front Panel, and see the table System
Installation on page 71 for a summary of connections and pin numbers.
NOTE: The system was evaluated by Underwriters Laboratory with our Front
Panel. If you provide a substitute front panel, the system may no longer be UL
compliant.
Customers can build an extension cable to place the Front Panel in a remote location. The
extension cable must conform to the following specifications:
Wire Size: must be larger than 26 AWG
l
Connectors: must be 15-pin, standard D-sub male and female
l
Maximum cable length is 10 meters
l
NOTE: The XMCP and XFP connectors can be interchanged without electrical
damage. However, neither the Front Panel nor the pendant will work properly
unless they are plugged into the correct connector.