  • Page 1 Operator's Manual Supplement Lift Guard™ Contact Alarm GR™-12 GR™-15 GR™-20 GRC™-12 First Edition First Printing Part No. 1293402GT...
  • Page 2 Note: These installation instructions only to continue to raise or drive the machine. The apply to the Genie models listed on the audible alarm and beacons will deactivate when the red Emergency Stop button is pushed in to the front cover.
  • Page 3: Pre-Operation Inspection

    First Edition • First Printing Operator's Manual Supplement Introduction Contact Alarm Safety Pre-operation Inspection Read, understand and obey all warnings and  Be sure that the operator’s, safety manual, instructions provided with the contact alarm. responsibilities manual and any necessary supplements are complete, legible and in the Do not exceed the rated platform capacity.
  • Page 4: Function Test

    Operator's Manual Supplement First Edition • First Printing Introduction Function Test Note: Perform this procedure from the platform controls in an area free of obstructions. Activate platform up. Move and hold the contact alarm in any direction. Platform up function stops, the beacons flash and the alarm sounds.
  • Page 5 First Edition • First Printing Operator's Manual Supplement Operating Instructions Operating Instructions Operating Instructions Contact alarm activated, beacon lights flash and an audible alarm sounds. Lift and drive functions will not operate from the platform controls. Note: The potential hazard must be acknowledged by the operator to continue operating the machine.
  • Page 6: Observe And Obey

    Operator's Manual Supplement First Edition • First Printing Introduction Introduction Attention: The Lift Guard™ Contact Alarm can only be installed on machines with the "Proportional Lift" control system. It is not compatible with "2 Speed Lift" control systems. Observe and Obey: Refer to the illustrations to determine which control system is on the machine.
  • Page 7: Tools Required

    Operator's Manual Supplement Introduction Tools Required: Contents of Kit 1293888GT 9/16 inch wrench GR-12 (CE / AS) 7/16 inch socket Description Genie part Qty. number 9/16 inch socket Cable tie, 11.5 inch / 29 cm 28443GT Ratchet Harness, GR-12 mast, CE...
  • Page 8 Operator's Manual Supplement First Edition • First Printing Introduction Contents of Kit 1294049GT Contents of Kit 1294052GT GR-15 (ANSI / CSA) GRC-12 Description Genie part Qty. Description Genie part Qty. number number Cable tie, 11.5 inch / 29 cm 28443GT...
  • Page 9: Installation Instructions

    Remove the white plugs from connector J1 pin 11 and C4 pin 6 and discard. Install the jumper wire assembly into J1 pin 11 and C4 pin 6. Genie part number 1294071GT. Install the receptacle locks set aside. 10 Secure the wire assembly inside the wire loom.
  • Page 10 21 Install the contact alarm harness with the GR-15 CE / AS 1293391GT squeeze connector into the junction box. Set the coil cord and jumper harness aside. Genie GR-15 ANSI / CSA 1293395GT part number 1293397GT. GR-20 CE / AS...
  • Page 11 Refer to the Software Update platform controls harness. Secure with cable section. ties. Refer to the Platform Mounting Location and Harness Routing. Genie part number 28443GT. 29 Mount the contact alarm assembly to the platform. 30 Connect the coil cord and jumper harness to the contact alarm and the harness from the junction box.
  • Page 12: Wiring Diagram

    Operator's Manual Supplement First Edition • First Printing Wiring Diagram Wiring Diagram Wiring Diagram - GR-12, GR-15, GR-20 - ANSI / CSA RESET RESET TEST LT BL LINE GR/YL Platform controls Harness Contact alarm harness Mast harness AC power outlet Lift Guard™...
  • Page 13 First Edition • First Printing Operator's Manual Supplement Wiring Diagram Wiring Diagram - GR-12, GR-15, GR-20 - CE / AS GR/YL LT BL Contact alarm harness Platform controls harness Platform overload switch Mast harness Part No. 1293402GT Lift Guard™ Contact Alarm...
  • Page 14 Operator's Manual Supplement First Edition • First Printing Illustration Illustration GR Platform Mounting Location and Harness Routing standard deck models extension deck models contact alarm insert mounting plate retaining fasteners Lift Guard™ Contact Alarm Part No. 1293402GT...
  • Page 15 17 Cut and discard the terminal from the white Install the jumper wire assembly into J1 pin wire inside the junction box. 11 and C4 pin 6. Genie part number 1294071GT. Install the receptacle locks set aside. 10 Secure the wire assembly inside the wire loom.
  • Page 16 25 Using the platform controls harness mounted to the platform as a guide, secure the wire assembly installed in the junction box to the platform using cable ties. Genie part number 28443GT. 26 Disconnect the platform controller and remove the old platform controls harness from the platform and discard.
  • Page 17 First Edition • First Printing Operator's Manual Supplement Wiring Diagram Wiring Diagram Wiring Diagram - GRC-12 LT BL LINE GR/YL Mast harness Platform controls harness AC power outlet (if equipped) Part No. 1293402GT Lift Guard™ Contact Alarm...
  • Page 18 Operator's Manual Supplement First Edition • First Printing Illustration Illustration GRC Platform Mounting Location and Harness Routing mounting location harness routing contact alarm mounting plate retaining fasteners Lift Guard™ Contact Alarm Part No. 1293402GT...
  • Page 19: Software Update

    First Edition • First Printing Operator's Manual Supplement Software Update Software Update Machines with a control system software revision Press the ground control scroll down button. of "P" or higher do not require a software upgrade. Result: The GCON LCD will show the software Machines with revision of "N"...
  • Page 20 Operator's Manual Supplement First Edition • First Printing Software Update Firmware Site Download Activating or Deactivating the Contact Alarm Note: Access to the internet is required to perform this procedure. Note: The contact alarm must be activated in the options menu for the machine to function properly Click on the Hyperlink below or open an when it has been installed on the machine.
  • Page 21 First Edition • First Printing Operator's Manual Supplement Software Update Pull out the red Emergency Stop button to the on position at the ground controls. Result: The ground controls LCD display will show the following: Use the ground control menu buttons to select machine Options.