JRC JMA-3300 Series Installation Manual page 51

Marine radar equipment
Hide thumbs Also See for JMA-3300 Series:
Table of Contents

Advertisement

3.8 CONNECTING TO THE GYRO AND ELECTROMAGNETIC LOG (NSK UNIT SETTING)
 Connecting the NSK unit
Insert the 8-pin connector (NSK) of CFQ-6998 (unit dedicated connection cable that is
enclosed by the NCT-4106A) to the connector of NCT-4106A.
 Connecting JMA-3300
Insert the 8-pin connector (IND) of CFQ-6998 (unit dedicated connection cable that is
enclosed by the NCT-4106A) to the connector of the display unit (J5).
Chapter 3 INSTALLATION OF THE DISPLAY UNIT
Connect the CFQ-6998 8-pin
connector.
3
3-21