STEP 1VH
970
STEP 2VH
DAY
STEP 3VH
REGEN
235
STEP 4VH
175
GAL
x1000
E1101
STEP 5VH
Cycle Sequence instructions allows the operator to set the order of the
cycle. The Softener System Setup allows the operator to set how long the
cycles will last. The operator may choose up to 9 cycles in any order.
END must be used as the last cycle option. The SOFTENING cycle
should only be used in brine prefill applications to allow salt to dissolve.
The following is an example of how to set a valve so that when regenera-
tion is initiated, BACKWASH occurs first, dn BRINE occurs second, RINSE occurs third, and FILL occurs fourth.
STEP 1CS
1.0
STEP 2CS
SET
14
VALVE HISTORY
(Can not be reset)
STEP 1VH – Press  and  simultaneously for three seconds, or until display changes and
release, then press  and  simultaneously and release. If screen in step 2VH does not appear
in 5 seconds the lock on the valve is activated.
STEP 2VH – Days, total since start-up: This display shows the total days since startup. Press
the NEXT button to go to Step 3VH. Press REGEN to return to previous step.
STEP 3VH – Regenerations, total number since start-up: This display shows the total number
of regenerations that have occurred since startup. Press the NEXT button to go to Step 4VH.
Press REGEN to return to previous step.
STEP 4VH – Volume, total used since start-up: This display shows the total gallons treated
since startup. This display will equal zero if a water meter is not installed. Press NEXT button to
go to Step 5VH. Press REGEN to return to previous step.
STEP 5VH – Error Log history: up to 10 errors. Press  and  buttons to view each recorded
error. If no errors have occurred " E 1 – –" is displayed. Press NEXT to exit valve history.
CYCLE SEQUENCE
STEP 1 CS – Press NEXT and  simultaneously until display changes, then release. Again
press NEXT and  simultaneously and release. If screen in step 2CS does not appear in 5 sec-
onds the lock on the valve may be activated.
STEP 2 CS – Meter Size. Use the or to select 1 for 1" ProMate-1.0 valve. Press NEXT to go
to Step 3CS. Press REGEN to exit cycle sequence.
Cycle Options
BACKWASH
DN BRINE
RINSE
SOFTENING
FILL
END