Eradicator Gen II O with EOG II Ozone Setup and Service Guide GALLONS REMAINING GALLONS REMAINING 1200 1200 CLOCK CLOCK REGEN REGEN NEXT NEXT Installation, Operation, and Service Manual 404 Moravian Valley Road • Waunakee, WI 53597 (608) 849-3050 • hellenbrand.com...
Manual Supplement Eradicator Gen II O Install & Service Guide Introduction This Advanced Features Supplement is a guide to the Eradicator with EOG II external Ozone. The Eradicator line of chemical free iron and sulfur removal systems is enhanced with ozone during the aeration cycle.
Manual Supplement Eradicator Gen II O Install & Service Guide Table of Contents Introduction ............................2 Eradicator with Ozone Overview - General Description ..............4-5 Installation of the EOG II ........................6 Installation - Inlet Check Valve Position ....................6 Power Supply for Ozone Generator ......................
Manual Supplement Eradicator Gen II O Install & Service Guide Gen II O with Ozone Overview The Eradicator Gen II O3, with ozone, is a breakthrough in chemical free filtration. The ozone is made from oxygen, then converts back to oxygen after its effective function. Ozone expedites the oxidation in the Eradicator’s aeration process.
Page 5
Manual Supplement Eradicator Gen II O Install & Service Guide Gen II O with Ozone Overview The EOG II Ozone system is mounted on the inlet side of the control valve with the wire harness going through the backplate to the circuit board. This allows the control valve and the O system to operate with a single power supply.
Manual Supplement Eradicator Gen II O Install & Service Guide Gen II O with Ozone Installation Mounting Clamp Set Power Supply Plug Clamp Screw Power Supply Transformer Jack Insert Power Supply Plug Here To mount the EOG II to the control valve, slide Attach O outlet tube the mounting ring over...
Manual Supplement Eradicator Gen II O Install & Service Guide Gen II O with Ozone Installation Ozone Resistant Air Draw Check Valve Assembly Tygon Ozone Resistant Tubing Check Valve The ozone resistant check valve is pre-inserted into the 3/8" Tygon Note: tubing.
Manual Supplement Eradicator Gen II O Install & Service Guide Gen II O with Ozone Installation EOG II Wire Harness Assembly Circuit board locking tab On the circuit board, unplug the power plug (4-wire), and the meter plug (3-wire) on the lower right side of the board, then the motor plug on the lower left side of the board.
Manual Supplement Eradicator Gen II O Install & Service Guide Gen II O with Ozone Installation Harness to EOG II Box Push the EOG II harness through the strain relief slot that the power cord went through. Pull through about 10” of the harness. Then make sure the wire is fully seated in the strain relief slot.
Manual Supplement Eradicator Gen II O Install & Service Guide Button Combination Quick Reference Guide NOTE: CLOCK NEXT REGEN When the Energy Saver is set to AUTO or ON, the dis- play backlight will turn off after 5 minutes of no activity. The first push of any button will turn the backlight on.
Page 11
Manual Supplement Eradicator Gen II O Install & Service Guide Button Combination Quick Reference Guide Regen Button REGEN From any user screen, Press and release REGEN to set a regeneration to occur at the next scheduled time. REGEN TODAY will alternate on top line of display when activated. Press and release again to deactivate.
Manual Supplement Eradicator Gen II O Install & Service Guide Gen II O with Ozone Setup Procedures Ozone Generator Programming Logic The Eradicator O functions just as a standard Eradicator Filter with the addition of ozone that is pro- duced during the air intake. The ozone is produced from ambient air that is entering the induction port during the Regeneration Down cycle.
Manual Supplement Eradicator Gen II O Install & Service Guide Setup Procedures Adjusting cycle times The following programming sequence is an example of changing the default draw time from 30 Min to 40 Min and the related Relay 1 adjustment for the longer cycle. From any User REGEN TIME TIME...
Manual Supplement Eradicator Gen II O Install & Service Guide Gen II O with Ozone Setup Procedures Start Up Plug the power supply into the receptacle. Refer to the main Eradicator manual for the instructions for the start up procedure. The programming for the O is already done for Eradicator O systems, so no further action is...
Manual Supplement Eradicator Gen II O Install & Service Guide Gen II O with Ozone Setup Procedures Special Considerations in Checking for Draw with Ozone Ozone is a gas that is made from oxygen. However, it can be an irritant to the eyes and respira- tory system.
Manual Supplement Eradicator Gen II O Install & Service Guide Gen II O with Ozone Wiring Diagram Ozone Components Wiring Guide The EOG II comes pre-assembled, wired, and is ready to connect to the Eradicator control. See the wire harness connection instructions to the conrol valve on page 9. The following diagram can be used for future service and trouble shooting if necessary.
Manual Supplement Eradicator Gen II O Install & Service Guide Gen II O with Ozone Repair / Replacement Parts WARNING ELECTRICAL HAZARD DISCONNECT POWER PILOT BEFORE SERVICING N.O. N.C. Replacement Part List Part No. Description Qty. 02910356 Ext EOG II Ozone Box Complete AS 02910331 CD Tube 02910361...
Manual Supplement Eradicator Gen II O Install & Service Guide Gen II O with Ozone Periodic Maintenance Special Considerations in Annual PM with Eradicator AIF with Ozone All Periodic Maintenance (PM) that is performed on Eradicator AIF systems annually should be done in addition to the following procedures when applied with ozone: 1.
Manual Supplement Eradicator Gen II O Install & Service Guide Gen II O with Ozone Periodic Maintenance Cleaning the Corona Discharge (CD) Tube The CD tube can be cleaned on site. It is recommended to stock extra CD tubes. Cleaning can be done in the shop, the clean tube tested, then swapped on location.
Manual Supplement Eradicator Gen II O Install & Service Guide Gen II O with Ozone Troubleshooting Condition Possible Cause Testing Solutions Place control in Regeneration DN / Draw. Check for Clean or replace internal valve parts, seal kit, No Air in Tank Unit Not Drawing Air draw at injector port injector, piston.
Page 21
Manual Supplement Eradicator Gen II O Install & Service Guide Gen II O with Ozone Troubleshooting Alarm Reset This table shows the Status light (diagnostic) parameters and their meaning. The Status light will tell you the state the EOG II system is in. Diagnostic LED It is useful to check normal operation and if there WARNING...
Page 22
Manual Supplement Eradicator Gen II O Install & Service Guide Gen II O with Ozone Troubleshooting Ozone Test - Isolating the CD Tube Brine Elbow When troubleshooting, it is helpful to test the CD tube for ozone production when it is isolated from the injector port.
Specifications ERADICATOR O3 IRON REMOVAL SPECIFICATIONS Requirements for proper MODEL AIFII 10 MAXIS O3 AIFII 13 MAXIS O3 operation: FACTORY PRESET MINUTES Backwash Minutes 8.00 Water Pressure: The system 8.00 will operate on a minimum of 20 Rinse DN Minutes 4.00 4.00 psi and a maximum of 100 psi.