STEP 1
STEP 2
STEP 3
Figure 9
STEP 1
STEP 2
STEP 3
STEP 4
STEP 5
RETURN TO
NORMAL MODE
Figure 10a
8
SET TIME OF DAY
Step 1 - Press SET CLOCK.
Step 2 - Current Time (hour): Set the hour of the day using  or  buttons. AM/PM toggles
after 12. Press NEXT to go to step 3.
Step 3 - Current Time (minutes): Set the minutes of day using  or  buttons. Press NEXT to
exit Set Clock. Press REGEN to return to previous step.
Power Loss - Lithium battery on circuit board provides up to 24 hours of time- clock backup
during power outages. After 24 hours, only the time of day needs to be reset, all other values are
stored in non-volatile memory. If a power loss last less than 24 hours and time of day is flashing,
replace coin type 2032 battery. Do not forget to reset for daylight savings time.
INSTALLER DISPLAYS/SETTINGS
Step 1 - Press NEXT and  simultaneously for 3 seconds.
Step 2 - Hardness: Set the amount of total compensated hardness in grains (hardness as
calcium carbonate) per gallon using  or  buttons. The default is 20 with value ranges from 1 to
150 in 1 grain increments. Note: The grains per gallon should be increased if soluble iron needs
to be reduced.
Add 3 grains of hardness for each ppm of iron present.
Step 3 - Day Override: This sets the number of days between regenerations. If value set to
"oFF" regeneration initiation is based solely on gallons used. If value is set as a number (allow-
able range from 1 to 28) a regeneration initiation will be called for on that day even if sufficient
number of gallons were not used to call for a regeneration. Set Day Override using  or  buttons:
• number of days between regeneration (1 to 28); or
• "oFF"
Press NEXT to go to step 4. Press REGEN to return to previous step.
Step 4 - Next Regeneration Time (hour): Set the hour of day for regeneration using  or 
buttons. AM/PM toggles after 12. The default time is 2:00 a.m. This display will show "REGEN"
on 0 GAL if system is set for immediate regeneration. Press NEXT to go to step 5. Press
REGEN to return to previous step.
Note: When installing this unit as part of a multi unit parallel system the regen time of day must
be adjusted to prevent multiple units from regenerating at the same time.
Step 5 - Next Regeneration Time (minutes): Set the minutes of day for regeneration using 
or  buttons. This display will not be shown if system is set for immediate regeneration. Press
NEXT to exit Installer Displays/Settings. Press REGEN to return to previous step.