Installer Manual 255/LOGIX 742-762-764 - Maintenance

9.4.2. Cleaning the injector

No.
A
Using a Torx key, unscrew and remove the injector cap (4).
Caution
Take care not to damage the injector (5).
B
Using pliers, gently extract the injector (5) from valve body.
C
Clean the injector (5) using compressed air, a soft brush or possibly a pin.

9.4.3. Cleaning the refill controller

No.
A
Using a Torx key, unscrew and extract the refill controller (3).
Clean the refill controller (3) with a soft brush.
B
Make sure the refill controller groove is perfectly clean.
C
Check for O-rings integrity.
D
Check for ball (2) integrity (if present).
E
Clean the refill controller chamber (1) before reinserting the refill controller (3).