3.
Description
3.1.
Technical specifications
Design specifications/ratings
Valve body ......................................................................... Glass-filled Noryl
Rubber components ......................................................... Compounded for cold water - NSF listed
Valve material certification .............................................. WQA Gold Seal Certified to NSF Std. 372
Weight (valve with controller)........................................... 1.8 kg
Recommended operating pressure ................................. 1.38 - 8.27 bar
Hydrostatic test pressure................................................. 20.69 bar
Water temperature ........................................................... 1 - 38°C
Ambient temperature ....................................................... 2 - 50°C
Flow rates (valve only)
Service at 1.03 bar
(15 psi) drop
(System)
Backwash at
1.72 bar (25 psi)
drop
(per valve)
Service Kv (Cv)
(per valve)
Backwash Kv (Cv)
(per valve)
* n corresponds to the number of valves in the system.
Ref. MKT-IM-021 / A - 20.02.2019
Twin Alternating
Single valve
(2 valves)
3
3.52 m
/h
3.52 m
3
1.36 m
/h
1.36 m
3
3.4 m
/h
(3.99 gpm)
(3.99 gpm)
3
1 m
/h
(1.2 gpm)
(1.2 gpm)
Installer Manual 255/LOGIX 742-762-764 - Description
material
(low lead compliance standard)
Twin Parallel
(2 valves)
3
/h
7 m
3
/h
1.36 m
3
3.4 m
/h
3.4 m
(3.99 gpm)
3
1 m
/h
1 m
(1.2 gpm)
®
- NSF listed material
Lockout "L"
(n valves)*
3
/h
n x 3.52 m
3
/h
1.36 m
3
3
/h
3.4 m
(3.99 gpm)
3
3
/h
1 m
/h
(1.2 gpm)
3
/h
3
/h
/h
13 / 92