Cleaning The Injector Valve; Cleaning The Refill Controller - Pentair AUTOTROL Performa 263 Installer Manual

Hide thumbs Also See for AUTOTROL Performa 263:
Table of Contents

Advertisement

9.2.2. Cleaning the injector valve

No.
A
Using a Torx key, unscrew and remove the injector cap (4).
A
Caution
Take care not to damage the injector (5).
B
Using pliers, gently extract the injector (5) from valve body.
C
Clean the injector (5) using compressed air, a soft brush or possibly a pin.
D
Reverse above procedure steps to rebuild.

9.2.3. Cleaning the refill controller

No.
A
Using a Torx key, unscrew and extract the refill controller (3).
Clean the refill controller (3) with a soft brush.
B
Make sure the refill controller groove is perfectly clean.
C
Check for O-rings integrity.
D
Check for ball (2) integrity (if present).
E
Clean the refill controller chamber (1) before reinserting the refill controller (3).
F
Reverse above procedure steps to rebuild.
Ref. MKT-IM-011 / A - 15.06.2017
Installer Manual Performa 263-268 / LOGIX 740-760 - Maintenance
Operation
Operation
45 / 64