2.4. 400V Class Specifications
400V Class Specifications
400V Class Specifications
400V Class Specifications
*1.
The rated input currents shown in the table are the values when the rated current is output. The values vary depending on
impedance on the power supply (wiring, breaker, input reactor option, etc.)
*2.
The power supply equipment capacities shown in the table are the values when 220V rated current is output. The values vary
depending on impedance on the power supply (wiring, breaker, input reactor option, etc.)
*3.
The setting of rated values for carrier frequencies [bb101] / [bb201] are internally limited in accordance with the description. Also, it
is recommended to set values equivalent to or above (maximum output frequency for driving ×10) Hz for the setting of carrier
frequencies [bb101] / [bb201]. Also, in the case of induction motor (IM) control, for items other than those subject to V/f control, it is
recommended to set carrier frequency at 2 KHz or more. In the case of synchronous motor (SM)/permanent magnet motor (PMM)
control, it is recommended to set carrier frequency at 8 KHz or more.
*4.
The value of the sensor-less vector control applied to the ND rating in the Standard motor. Torque characteristics may vary
depending on the control method and the motor used.
*5.
Based on self-declaration.