AMX NI-700 Webconsole & Programming Manual page 15

Netlinx integrated controllers firmware version 4.0 or higher
Hide thumbs Also See for NI-700:
Table of Contents

Advertisement

Communication Settings dialog - Recent tab
FIG. 4
4.
Select NetLinx Master under Platform Selection to indicate you are working with a NetLinx Master.
5.
Select the Serial tab to view the serial options (FIG. 5).
Communications Settings dialog - Serial tab
FIG. 5
6.
On the Serial tab, set the COM port parameters (used to communicate to the NetLinx Master).
Default serial settings for NetLinx Masters are:
7.
Click OK to close the Communication Settings dialog.
8.
Note that the serial configuration is indicated in the Conf iguration text field (FIG. 6):
NetLinx Integrated Controllers (Firmware v4)- WebConsole & Programming Guide
• Comm Port:
COM 1
• Baud Rate:
38400
• Data Bits:
8
• Parity:
None
• Stop Bits:
1
• Flow Control:
None
Initial Configuration
15