Installation Safety Instructions

The unit must be installed by a suitably qualified person in
accordance with the latest IEE Wiring Regulations.
Isolate mains supply before commencing installation.
Please read all instructions before proceeding.
Ensure that the fixed wiring connections to the mains
supply is via a fuse rated at not more than 6 amps and class
'A' switch having a contact separation of a minimum of
3mm in all poles. The recommended cable sizes are
1.0mm sqr or 1.5mm sqr. No earth connection is required
as the product is double insulated but ensure continuity of
earth throughout the system.

General Safety Instructions

When fitting batteries, do not mix old and new batteries
together. Do not use rechargable batteries.
This product complies with the essential requirements of
the following EC Directives:
• Electro-Magnetic Compatibility Directive 2004/108/EC
• Low Voltage Directive 2006/95/EEC
• EC Marking Directive 93/68/EEC
Please leave the user instructions with the end user where
they should be kept in a safe place for future reference.