Clearance Dimensions - Fisher & Paykel OR90 Series Installation Manual

Dual fuel freestanding cooker
Hide thumbs Also See for OR90 Series:
Table of Contents

Advertisement

F
ISO

CLEARANCE DIMENSIONS

A
Minimum vertical distance between benchtop and cabinet extending above counter
B
Minimum clearance from left and right edge of cooker to nearest vertical combustible surface
C
Minimum clearance from cooking surface to:
– Overhead cabinet centered above the cooktop– Ventilation hood centered above the cooking surface
D
Width of cabinetry opening
E
Maximum height of cabinetry immediately adjacent to the cooker (from floor to countertop)*
F
Maximum depth from wall to cabinetry face
* Depending on the height of the feet adjustment. The cooking surface must sit flush or above benchtop level.
8
8
CLEARANCE DIMENSIONS
A
b
COOKING SURFACE
e
Electrical & Gas
(see diagrams following)
d
FRONT
OR90 DUAL FUEL
C
b
mm
450
200
650
900
946
600
Note
The cooker must be installed by a
suitably qualified technician and in
compliance with local safety standards.
This cooker has class "2/1" overheating
protection so that it can be installed
next to a cabinet
If the cooker is installed adjacent to
furniture which is higher than the gas
hob cooktop, a gap of at least 200 mm
must be left between the side of the
cooker and the furniture.
The walls and kitchen furniture
surrounding the appliance must be
made of non-flammable material. Any
veneered synthetic material and the glue
used must be resistant to a temperature
of 90°C in order to avoid ungluing or
deformations. It is recommended that a
10 mm gap to each side is made if the
adjacent kitchen furniture is made of a
plastic laminate wrap.
Curtains must not be fitted immediately
behind appliance or within 500 mm of
the sides.
Installing the cooker on a plinth
We do not recommend the cooker
is installed on a plinth. If this is
unavoidable, the cooker can be installed
on a plinth without the adjustable feet
fitted.
Ensure the cooker is secure and provide
safety measures to keep it in place.
Cabinetry dimensions can be adjusted
to suit the plinth height, see product
dimensions for chassis height.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Or90scg4Or90sdg4Or90scg6Or90sdg6

Table of Contents