IMPORTANT!
This cooker must be connected to the mains power supply only by a suitably qualified person in accordance with current regulations.
This cooker must be earthed.
The appliance must be connected to the mains checking that the voltage corresponds to the value given in the rating plate and that the electrical
cable sections can withstand the load specified on the plate.
It is recomended that the appliance is connected via a dedicated cooker circuit using a double pole cooker switch with a rating equal or greater
than the total loading of the cooker, with a minimum opening between the contacts of 3 mm.
Alternative connection methods may be available as long as they conform to current IEE wiring regulations.
The power supply cable must not touch the hot parts and must be positioned so that it does not exceed 75°C at any point.
Once the appliance has been installed, the switch or socket must always be accessible within 2 metres.
Before carrying out any work on the electrical parts of the appliance, the appliance must be disconnected and locked off from the mains.
This appliance must be connected to the electrical supply using a cable fitted with an appropriately rated plug. The plug must be compatible with
the socket-outlet fitted to the final subcircuit in the fixed wiring that is intended to supply the appliance.
Replacing the power cord
If the power supply cable is damaged it must be substituted by a suitable cable available in the after sales service.
14