Sony PWS-4500 Operation Manual page 53

Multi port av storage unit
Hide thumbs Also See for PWS-4500:
Table of Contents

Advertisement

1)
Code
Indication
300200
POWER SUPPLY B INVALID INPUT VOLTAGE
470100
RTC BATTERY LOW LEVEL
(RTC BATT LOW)
7401pp
PORT x ASYNCHRONOUS VIDEO INPUT
(P-x ASYNC VIN)
740200
ASYNCHRONOUS SHARE PLAY INTERFACE
74.03.ii
xx ASYNCHRONOUS INTERFACE
75.01.ii
SHARE PLAY x INTERFACE DEFECTIVE
B902pp
PORT x SYS2 PROCESS DELAYED
BB01pp
PORT x NMI COMMUNICATION ERROR
D104pp
PORT x DIO-DM DMA ERROR
D204pp
PORT x DATA READ ERROR IN SHARE PLAY
E10101
MEMORY FULL, NOT RECORDABLE
(M1 FULL)
E10201
MEMORY COND3 BAD, NOT RECORDABLE
(M1 COND3 BAD)
E10301
MEMORY FUNCTION LIMIT
(M1 FUNC LIMIT)
E10501
MEMORY MAXIMUM FILES, NOT
RECORDABLE
(M1 MAX FILES)
E10601
MEMORY FILE SYSTEM STUFFED, NOT
RECORDABLE
(M1 FS STUFFED)
E202pp
PORT x FULL, STOP RECORDING
(P-x FULL STOP)
E401pp
PORT x NMI LINK RESOURCE LACK
1) The portion in lower case letters in the above codes is one of the following
numbers.
pp: Number identifying the corresponding port.
81: Port A
82: Port B
83: Port C
84: Port D
ii: The following characters indicate the input/output interface.
91: SHARE PLAY1
92: SHARE PLAY2
A1: NMI LAN A1
A2: NMI LAN A2
A3: NMI LAN B1
A4: NMI LAN B2
A5: NMI LAN C1
A6: NMI LAN C2
A7: NMI LAN D1
A8: NMI LAN D2
2) Information in parentheses () indicates short messages for superimposed
display.
2)
Description
The input voltage applied to power supply unit B is
incorrect.
Check the applied power supply voltage.
The lithium battery on the SY-422 board is low on power.
The HD SDI input signal for the indicated port is out of
phase by ±4H or more from the reference signal.
The SHARE PLAY input signal phase is out of phase by
±2H or more from the reference signal.
NMI Leader is out of phase by ±0.5H or more from the
reference signal.
Link is down, regardless of whether SHARE PLAY IF is
enabled.
A SYS2 software processing delay occurred.
There was not response to the NMI command.
DMA transfer between the DIO board and DM board was
not completed successfully.
The may be noise in the recorded data.
An access error to target storage occurred during SHARE
PLAY execution.
The recording operation/command was terminated
because there was insufficient remaining recording
capacity in memory.
Deletes files from memory.
Cannot record because the swap space to replace bad
memory cells has been consumed in memory. The
recording operation/command was terminated.
The recording/playback operation was terminated due to
memory function limits related to recording and playback.
The recording operation/command was terminated
because the number of files in memory has reached the
upper limit.
Deletes files from memory.
The recording operation/command was terminated
because the memory file system control limits have been
reached.
Format the memory to use it for recording.
Recording was terminated for the indicated port because
the memory is full.
An error was detected relating to the control from PRCM.
53
Troubleshooting

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents