Control Specification (09/12 Class); Mode Hierarchy - Daikin FTXS09DVJU Service Manual

Inverter pair wall mounted type
Hide thumbs Also See for FTXS09DVJU:
Table of Contents

Advertisement

Control Specification (09/12 Class)

3. Control Specification (09/12 Class)

3.1

Mode Hierarchy

Outline
There are two modes; the mode selected in user's place (normal air conditioning mode) and forced
operation mode for installation and providing service.
Detail
For heat pump model
Note:
Unless specified otherwise, an indoor dry operation command must be regarded as cooling
operation.
34
There are following modes; stop, cooling (includes drying), heating (include defrosting)
Air conditioner control mode
Forced operating mode
Forced cooling (for Pump Down Operation)
Normal operating mode
Cooling
Heating
Defrosting
Stop mode (except for cooling/heating modes by indoor command)
Preheat operation
During C (capacitor) is discharging
Stop
SiUS04-702
(R2829)
Function and Control

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents