RX09/12FVJU
3.6
Removal of
Procedure
Step
1. Remove the compressor.
Unscrew the nut of the
1
compressor.
Before working,
make sure that the
refrigerant is empty
in the circuit.
Be sure to apply
nitrogen
replacement when
heating up the
brazed part.
246
Compressor
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
SiUS04-702
Points
Warning
Ventilate when refrigerant
leaks during the work.
(If refrigerant contacts fire, it
will cause to arise toxic gas.)
Provide a protective sheet or
a steel plate so that the
brazing flame cannot
influence peripheries.
Be careful so as not to burn
the compressor terminals or
the name plate.
Be careful so as not to burn
the heat exchanger fin.
Warning
Since it may happen that
refrigeration oil in the
compressor will catch fire,
prepare wet cloth so as to
extinguish fire immediately.
Removal Procedure