Daikin FTXS09DVJU Service Manual page 289

Inverter pair wall mounted type
Hide thumbs Also See for FTXS09DVJU:
Table of Contents

Advertisement

RX15/18/24FVJU
Step
Unscrew the nut of the
3
compressor.
Remove the putty of the
4
accumulator.
Before working,
make sure that the
refrigerant is empty
in the circuit.
Be sure to apply
nitrogen
replacement when
heating up the
brazed part.
Heat up the brazed part
5
of the discharge side
and disconnect.
6
Heat up the brazed part
of the suction side and
disconnect.
Lift the compressor up
7
and remove it.
278
Procedure
SiUS04-702
Points
Warning
Ventilate when refrigerant
leaks during the work.
(If refrigerant contacts fire, it
will cause to arise toxic gas.)
Provide a protective sheet or
a steel plate so that the
brazing flame cannot
influence peripheries.
Be careful so as not to burn
the compressor terminals or
the name plate.
Be careful so as not to burn
the heat exchanger fin.
Warning
Since it may happen that
refrigeration oil in the
compressor will catch fire,
prepare wet cloth so as to
extinguish fire immediately.
Removal Procedure

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents