SiUS04-702
Step
2. Disconnect harnesses.
Loosen the fixing screw
1
of the
cable way
board.
2
Push the hook up to
release the cable way
board.
Open the cable way
board.
3
Disconnect the
harnesses from the
power supply PCB.
HL
(black) ···· to the
terminal strip
HE2
(yellow / green) ····
to the terminal strip
(earth)
HAC1
(black) ···· from
the control PCB (AC1)
HE1
(yellow / green) ····
from the control PCB
(E)
Removal Procedure
Procedure
RX15/18/24FVJU
Points
Service monitor PCB
LED A (Green)
LEDA(Green)
S52
SW1
ON
SW4
A B C
SW4
(Initial setting: OFF)
(R2704)
Power supply PCB
HE1
V3(varistor)
HAC1
HE2
HL
FU1 250V 30A
(soldered)
(R2707)
263