SDI

A
VAILABLE FOR
D
A complex command that can be used to check the status of the SDI-12
ESCRIPTION
subsystem, as well as configure it.
P
The command has a multitude of options. If issued without parameters, the GET
ARAMETERS
variant is implied, i.e. the status of the SDI-12 subsystem will be returned (see also
below). The full extent of the commands is not given here as the the SDI-12
subsystem is configured via the wireless link by using the GUI configurator in the
A840 Telemetry Gateway. Additional information can be obtained from Adcon
Telemetry upon request.
R
Following information is supplied in the form of a string of characters (the GET
ETURNS
variant):
In addition, for every programmed SDI-12 sensor, following information will be
listed:
Note:
For further information about the significance of the above terms please refer to the
SDI-12 standard specification, version 1.3 (http://www.sdi-12.org).
R
SET/GET.
EMARKS
R
Yes.
EMOTE
E
12225 sdi
XAMPLE
A731
A732
A733
a/A — The presence of the SDI-12 adapter: a absent, A present
w/W — The system is in wait state: w not waiting, W waiting for an SDI-12
sensor
m/M — Measurement command started: m no measurement is being done,
M a measurement is in progress
v/V — Values for storage available: v no values are available, V values are
available for local storage
d/D — autodiscovery initiated: d no autodiscovery pending, D
autodiscovery pending (will be done at the next sensor poll cycle)
sensor id — the sensor ID in ASCII (0 - 9, A - Z and a - z)
method + CRC — the measuring method, either M (normal) or R
(continuous), optionally followed by the CRC flag (C)
index — the indices used (in hexadecimal), e.g. 0x3 if indices 0 and 1 are
used
Performing Advanced Functions