Slot; Sst; Pmp - Adcon A73 addWAVE Series User Manual

Rtus
Table of Contents

Advertisement

SLOT

C
Changing these parameters might adversely affect the ability of the device to
AUTION
operate for extended periods under low solar radiation conditions.
A
VAILABLE FOR
D
Sets/returns the node's sampling interval and rate.
ESCRIPTION
P
The interval (60 - 65535) and rate (0 - 255). The interval represents the time (in
ARAMETERS
seconds) elapsed between two slots stored in the internal memory, while the rate
represents the numbers of samples used to build the average that will be stored.
R
The interval and rate.
ETURNS
R
GET/SET. The default interval is 900 (15 minutes) and rate is 15 (15 samples per
EMARKS
quarter of an hour).
R
Yes, SET only.
EMOTE
E
SLOT 900 15
XAMPLE
9193 SLOT 0
#
SLOT
9193 SLOT 900 15 0
#

SST

AVAILABLE FOR
DESCRIPTION
Sets/returns the RTU sensor's settling time, which is the time that elapses between
powering the sensors and sampling them. Default value is 2 seconds.
PARAMETERS
The settling time in seconds.
RETURNS
The current settling time.
REMARKS
GET/SET.
REMOTE
Yes, SET only.
EXAMPLE
SST 3
9193 SST 0
#
SST
9193 SST 3 0
#

PMP

A
VAILABLE FOR
D
Sets/returns the node's Power Management Parameters (switches on/off the
ESCRIPTION
battery charge).
P
The lower (switch on) and the higher limit (switch off), both in volts x 10. Standard
ARAMETERS
Values are 65 (for 6.5 Volts) for switch on and 72 (for 7.2 Volts) for switch off (for a
standard 6.2 Volt NiCd battery). From these values, other thresholds are internally
computed.
R
The lower (switch on) and the higher limit (switch off), both in volts x 10.
ETURNS
R
GET/SET.
EMARKS
A731
A732
A733
A731
A732
A733
A731
A732
A733
Performing Advanced Functions
A733GSM
A733GSM
A733GSM
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

A733A731A733gsmA732

Table of Contents