SCALANCE X414-3E power module

The power module is located in slot 2.

 T he power module can be supplied with power redundantly over two inputs. The two power
inputs are isolated from each other, there is no power distribution. If redundant power feed-in
is used, the switch is supplied solely by the section of the power module with the higher
output voltage.
The front 4-pin connector is used for the power supply. The input voltage is 24 V DC (20.4 –
28.8 V). The signaling contact supplies the fault status at the rear 4-pin connector. If there is
a fault, the contact opens.
Figure 3-11
Slot of the power module
Signaling contact
The following can be signaled over a floating signaling contact:
● Power failure.
The power supply monitored is selected in the fault mask.
● Bad link status of a port.
(Bad connector or no connection to partner device). The port monitored is selected in the
fault mask.
● Change to the DIL switch during operation.
Possible inconsistency between the switch setting and the actual operating state, The
switch setting is adopted only after a restart.
If the SCALANCE X414-3E is set as the redundancy manager, the following errors are also
reported:
● Bad link status of the ring ports, regardless of the status of the fault mask.
● Configuration of a second IE Switch X-400 as redundancy manager in the same ring.
SCALANCE X-400
Operating Instructions, 06/2015, C79000-G8976-C186-12
Description