Technical specifications
8.1 SCALANCE X414-3E and X408-2 - technical specifications
Current consumption at 24 V DC < 2000 mA
Load on the signaling contact
Overvoltage protection at input
Digital Inputs
C-PLUG
Dimensions (width x height x
depth)
Weight
Power consumption
Memory capacity
Permitted cable lengths
TP cable length
Redundancy reconfiguration times
Redundancy
HRP
Standby link
MRP
140
SCALANCE X414-3E
24 V DC / max. 100 mA safety
extra-low voltage (SELV)
Non-replaceable fuse (F 3.15 A /
250 V)
Input voltage:
Rated value 24 V DC safety
extra-low voltage (SELV)
For state "1": + 13 V ...+ 30 V
For state "0": – 30 V to + 3 V
Max. input current: 8 mA
Max. cable length: 30 m
Inputs isolated from electronics.
SCALANCE X414-3E
24.3 x 17.0 x 8.1 mm
approx. 5 g
0.015 W
32 Mbytes
SCALANCE X414-3E
With TP cord up to 10 m,
 with
FastConnect cabling system up
to 100 m.
Reconfiguration times
300 ms
300 ms
200 ms
Operating Instructions, 06/2015, C79000-G8976-C186-12
SCALANCE X408-2
< 700 mA
24 V DC / max. 100 mA safety
extra-low voltage (SELV)
Non-replaceable fuse (F 3 A /
32 V)
Inputs not present.
SCALANCE X408-2
24.3 x 17.0 x 8.1 mm
approx. 5 g
0.015 W
32 Mbytes