Configuration / project engineering
6.4 Operator controls
Switch
Status
Meaning
R1
ON
You can only configure ring redundancy with software (CLI, WBM).
"Automatic Redundancy Detection" is set as the mode.
R2
ON
With this setting, you cannot enable Rapid Spanning Tree / Span-
ning Tree.
For more detailed information, refer to the configuration manual
"SCALANCE X-300 and SCALANCE X-400 Industrial Ethernet
Switches".
Configurable ring ports
With the R1 and R2 switches, you can specify the ring ports on slots 5 to 7.
Figure 6-3
Ring ports configurable with the R1 and R2 switches