Detroit Diesel EPA07 Series 60 DDEC VI Troubleshooting Manual page 826

Table of Contents

Advertisement

113.1
SPN 3597/FMI 3
[a] If the resistance is less than 5 Ω, repair the short to ground between pin 93 of the
MCM 120–pin connector and the rear injector valve cover connector, turbo actuator
connector and or fan control solenoid. Refer to section 113.1.1.1.
[b] If the resistance is greater than 5 Ω, contact the Detroit Diesel Customer Support
Center at 313–592–5800 for MCM replacement.
113.1.1.1
Verify Repairs
Verify repairs as follows:
1. Turn ignition OFF.
2. Reconnect any electrical connections that were disconnected to perform the diagnosis.
3. Clear codes with DDDL 7.0 or latest version.
4. Start and bring engine up to operating temperature (over 140°F/60°C).
5. Verify operation is satisfactory and no warning lamps illuminate. If warning lamps
illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel
Customer Support Center at 313–592–5800.
113-4
All information subject to change without notice.
Copyright © 2007 DETROIT DIESEL CORPORATION

Advertisement