SPN 3609/FMI 20
DPF Inlet Pressure Sensor Drifted High In Range Fault (Low Box),
DPF Inlet Pressure
DPF Inlet Pressure Sensor
RPM: 575–650, Torque: –100–150 N·m
None
Continuous when enabling conditions are met
10 seconds
SPN 3609/FMI 21
DPF Inlet Pressure Sensor Drifted Low In Range Fault (High Box),
DPF Inlet Pressure
DPF Inlet Pressure Sensor
RPM: 1400–1700, Torque: 1700–2300 N·m
None
Continuous when enabling conditions are met
15 seconds
SPN 3610/FMI 3
DPF Outlet Pressure Circuit Failed High, voltage of sensor > 4.785 volts
DPF Outlet Pressure Sensor
Always Enabled
None
Always Enabled
2 seconds
SPN 3610/FMI 4
DPF Outlet Pressure Circuit Failed Low, voltage of sensor < 0.1515 volts
DPF Outlet Pressure Sensor
Always Enabled
None
Always Enabled
2 seconds