Detroit Diesel EPA07 Series 60 DDEC VI Troubleshooting Manual page 306

Table of Contents

Advertisement

18.2
ENGINE MANUFACTURER DIAGNOSTICS PARAMETER DESCRIPTIONS
Description
Monitored Parameter
Typical Enabling Conditions
Monitor Sequence
Execution Frequency
Typical Duration
Description
Monitored Parameter
Typical Enabling Conditions
Monitor Sequence
Execution Frequency
Typical Duration
Description
Monitored Parameter
Typical Enabling Conditions
Monitor Sequence
Execution Frequency
Typical Duration
Description
Monitored Parameter
Typical Enabling Conditions
Monitor Sequence
Execution Frequency
Typical Duration
18-22
SPN 2798/FMI 596.1
Injector Spill Control Valve Cylinder 4,5,6 Shorted to Battery, driver
status = short circuit
Fuel Injector - Spill Control Bank 2
Always Enabled
None
Always Enabled
< 5 seconds
SPN 2798/FMI 696.4
Injector Spill Control Valve Cylinder 4, 5, 6 Shorted to Ground, driver
status = short circuit
Fuel Injector - Spill Control Bank 2, cyl 4,5,6
Always Enabled
None
Always Enabled
< 5 seconds
SPN 3246/FMI 0
DPF Outlet Temperature Too High, DPF temperature out > 760°C
Diesel Particulate Filter
Always Enabled
None
Always Enabled
2 seconds
SPN 3246/FMI 3
DPF Outlet Temperature Sensor Failed High, voltage of sensor > 2 volts
DPF Outlet Temp
Always Enabled
None
Always Enabled
2 seconds
Copyright © 2007 DETROIT DIESEL CORPORATION
All information subject to change without notice.