6 Maintenance
The battery master switch must be on and the
engine must be stopped; the starter key on
the control panel must be in the OFF position.
48
13 Draining the oil
Connect a Ø 10 mm hose to the crankcase oil-
change pump as shown.
Open the shut-off valve 'A' .
Turn on the oil-change pump with the switch 'S' .
Turn off the pump when all the oil is pumped
out of the crankcase.
D
anger
Beware of burns from hot oil.
A
S
The engine oil must be disposed in accord-
ance with the applicable environmental reg-
ulations.
Engine oil change
Every 100 operating hours.
OPEN