11 Operating media
C
aution
Do not mix oil of different brands together.
Oils of different brands are mostly not com-
patible with each other. If they are mixed, the
mixtures can cause components such as pis-
ton rings, cylinders etc. to seize up and cause
wear to moving parts. The best thing is to
keep to one brand and one type of lubricating
oil for each subsequent service.
Limits concerning motor oil
Characteristic
Viscosity
Total base numberl (HCl)
Total acid number
Water content
Flash point
Pentane insolubles
Coagulated pentane insolubles
Limits concerning motor oil
If an analysis of the used lubricating oil is con-
ducted to determine its condition, consult the
overview below. Change the oil if one or more
of the conditions is not met.
Unit
cSt @ 100°C
mgKOH/g
mgKOH/g
% volume
°C
% weigth
% weight
- How often the oil has to be changed de-
pends on the characteristics of the fuel.
Only use the recommended fuels.
- The limit for the total base number is half
of that of new oil in the case of an analysis
method based on perchloric acid.
Test method
JIS: K 2283
JIS: K 2501
JIS: K 2275
JIS: K 2265
ASTM: D 893
Lubricating oil
n
ote
Limit
+30% / -15% max.
for new oil
2.0 min.
+3.0 max. for new oil
0.2 max.
180 min.
0.5 max.
3.0 max.
117