Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.

MOTOR WiNDiNG TeST

MXR20 - 65 motors have 3 motor winding
wires, 3 black, 1 green (ground)
1. Unplug washer or disconnect power.
2. To gain access to the inverter connections,
remove the rear panel, loosen the Phillips
screw securing the inverter cover, and
remove the cover.
3. Remove wire cover from bottom of the
inverter by gently squeezing in on the sides
and pulling it down away from the inverter.
4. Ohm test for shorted winding by checking
each motor lead to ground and the reading
should be an open circuit (infinite Ω).
5. Motor wires connected to inverter drive
and to motor junction box are marked
"1", "2" and "3" in all MXR20 - 65 models.
Resistance measurements are made from
"1" to" 2", "2" to" 3", and from "1" to "3" as
noted in the table below.
NOTe: Make sure the inverter wire cover,
and front cover and screw as well as any
removed wire ties are reinstalled or properly
replaced.
Model
MXR20PDA/PNA
MXR25PDA/PNA
MXR30PDA/PNA
MXR40PDA/PNA
MXR55PDA/PNA
MXR65PDA/PNA
Resistance (Ohms / Ω)
7.4Ω, 7.4Ω, 7.4Ω
5.9Ω, 5.9Ω, 5.9Ω
4.5Ω, 4.5Ω, 4.5Ω
4.5Ω, 4.5Ω, 4.5Ω
2.3Ω, 2.3Ω, 2.3Ω
2.2Ω, 2.2Ω, 2.2Ω
Electrical Shock Hazard
OTHeR COMPONeNT
ReSiSTaNCe CHaRT
Component
Door Lock Coil
Drain Valve
Contactor Coil
Control Board (P1 to P3 on
control board)
Elbi Inlet Valve Coil
(3 - 4 way valve)
Danfoss Inlet Valve Coil
4-8
Resistance
(Ohms / Ω)
2.9K - 3.1KΩ
120Ω
525Ω
160Ω
3.75KΩ
1.35KΩ