16. Unscrew the #2 Phillips screw securing
the inverter front cover. Remove cover. The
screw does not come out of the cover.
#2 Phillips
Screw
17. Disconnect the RJ-45 inverter
communication wire by pressing the thumb
tab and pulling the connector out.
18. Remove the bottom inverter cover by
squeezing in on both sides of the cover to
release the locking clips. Slide the cover
down and out the back of the washer.
RJ-45
Wire
3-50
19. Mark the wires from the drive motor to
the inverter for proper reinstallation. These
wires are connected to contacts U, V and W
of the inverter.
TeCH TiP: Changing the order of any two
drive motor wire connections on the inverter
will change rotation direction of drive motor.
20. Use a flat blade or Phillips screwdriver to
loosen the screws on contacts U, V and W.
21. Pull the drive motor wire connectors down
to remove them.
22. Loosen the ground wire screw and pull the
connector down to remove it.
23. Remove the motor from the washer.