Operation And Maintenance Manual - Kohler KD36V16 Operation And Maintenance Manual

Table of Contents

Advertisement

Operating fluids and maintenance
Maintenance activities
82
Fig. 62: V-ribbed belt drive
u Remove fan. See the generator set's operating manual.
u Release hex screw 1 (M12 8.8).
u Loosen rigging screw 2 (M10 10.9).
u Remove the V-ribbed belt 3.
u Check that the belt pulleys and tensioning device are in perfect working order
and check their play (for example, tread wear on the belt pulleys).
w Replace the damaged parts. Contact Kohler.
u Place new V-ribbed belts on all belt pulleys and tightening roller, making sure
that they are properly seated.
u Turn rigging screw 2 (M10 10.9) until tensioned.
w Check tension with an appropriate frequency device.
Own frequency is 111 Hz:
u Tighten hex screw 1 (M12 8).
u Start the engine and let it run for 30 minutes.
u Turn off engine and check pretension. Retension if necessary.
u Install the fan. See the generator set's operating manual.
© 2018 by Kohler Co. All rights reserved.

Operation and Maintenance Manual

KD36V16 33521029701_1_1 en 2018-08-01