Secure And Release The Diesel Engine Against Accidental Starting; Operation And Maintenance Manual - Kohler KD36V16 Operation And Maintenance Manual

Table of Contents

Advertisement

Safety
Operating areas and maintenance areas
2.8.4 Secure and release the diesel engine against
30
Fig. 21: Safety zones during maintenance and repairs
a
Horizontal projection (viewed from
above)
Access is allowed to the following areas:
– Safety zone, unit carrier side A
– Safety zone next to engine B
– Safety zone, flywheel side C
– Safety zone, above engine D
Access is prohibited to the following areas:
– Safety zone, below engine E
Access to the maintenance areas must be secured against accidental starting
before entering the safety zones.
accidental starting
Access to the maintenance areas must be secured against accidental starting
before entering the safety zones.
Procedure:
Secure the Diesel engine against any unexpected start-up:
– Disconnect diesel fuel supply.
– Label cut-off point.
– Disconnect electrical power supply and secure against reactivation.
– Label cut-off point.
Make the diesel engine ready for operation (release):
– The following work has been completed:
Installation activities
Maintenance activities
Repair activities
– Make sure that all foreign bodies have been removed.
– All of the protective devices are installed and are working properly.
– Make sure that no external persons stand or walk in the danger zones.
© 2018 by Kohler Co. All rights reserved.

Operation and Maintenance Manual

b
Upright projection (viewed from
the flywheel side)
KD36V16 33521029701_1_1 en 2018-08-01

Hide quick links:

Advertisement

Table of Contents
loading