Extended Storage - Stoelting Endura 131 Service Manual

Table of Contents

Advertisement

1.
PRODUCT SAFETY – Strong acids are
dangerous chemicals and handling them
requires safety.
2.
MACHINE DAMAGE – Strong acids will attack
metal and rubber causing premature wear of
parts. The use of a delimer needs to be closely
monitored to avoid damage to machine surfaces
and parts.
With proper daily use of STERA-SHEEN or it's
equivalent, there is no need for the use of a DELIMER.
DO NOT USE BLEACH
·
BLEACH HAS ABSOLUTELY NO CLEANING
PROPERTIES.
·
BLEACH IS CORROSIVE. It can and will
damage components of the machine causing
premature wear and metal corrosion.
GENERAL PURPOSE CLEANERS
General purpose cleaners do not have the ability to
remove milkstone. Milkstone will become a problem
if not remedied with additional products and
procedures.
THE USE OF CHLORINE TEST STRIPS
"Test strips" are used to determine concentrations of
active chlorine in sanitizing solutions. To use the strips,
tear off a small portion and submerge it into the
sanitizing solution. Then, compare the color change to
the color key on the side of the test strip dispenser to
determine the approximate chlorine concentration.
The ideal concentration of chlorine needs to be 100 ppm
(as stated by the FDA).
Follow the directions on the container for proper
concentration.
There are two main factors that contribute to falling
chlorine concentrations in a sanitizing solution.
1.
PRODUCT USE – As the chlorine in the
solution is being used, chlorine concentrations
fall.
2.
TIME – As time passes, small amounts of
chlorine "evaporate" from the solution. (That is
why you can smell it.)
NOTE
Sanitizing solutions should not be allowed to fall below
100 ppm chlorine. New solutions should be mixed once
old solutions become ineffective.
NEVER ATTEMPT TO REPAIR OR PERFORM
MAINTENANCE ON FREEZER UNTIL THE MAIN
ELECTRICAL
DISCONNECTED.
B. DAILY
1.
The exterior should be kept clean at all times to
preserve the lustre of the stainless steel. A mild
alkaline cleaner is recommended. Use a soft
cloth or sponge to apply the cleaner.
DO NOT USE ACID CLEANERS, STRONG
CAUSTIC COMPOUNDS OR ABRASIVE
MATERIALS TO CLEAN ANY PART OF THE
FREEZER EXTERIOR OR PLASTIC PARTS.
C. WEEKLY
1.
Check "O" Rings and rear seal for excessive
wear and replace if necessary.
2.
Remove the drip tray by gently lifting up to
disengage from the support and pulling out.
Clean behind the drip tray and front of the
freezer with a soap solution.
16
WARNING
POWER
HAS
BEEN
CAUTION

Advertisement

Table of Contents
loading

This manual is also suitable for:

E131gF131gFutura 131

Table of Contents