2.2

SHIPMENT AND TRANSIT

The freezer has been assembled, operated and
inspected at the factory. Upon arrival at the final
destination, the complete freezer must be checked for
any damage which may have occurred during transit.
With the method of packaging used, the freezer should
arrive in excellent condition. THE CARRIER IS
RESPONSIBLE FOR ALL DAMAGE IN TRANSIT,
WHETHER VISIBLE OR CONCEALED. Do not pay the
freight bill until the freezer has been checked for damage.
Have the carrier note any visible damage on the freight
bill.
If concealed damaged and/or shortage is found later,
advise the carrier within 10 days and request inspection.
The customer must place claim for damages and/or
shortages in shipment with the carrier. Stoelting, Inc.
cannot make any claims against the carrier.
2.3

FREEZER INSTALLATION

Installation of the freezer involves moving the freezer
close to its permanent location, removing all crating,
setting in place, assembling parts, and cleaning.
A. Uncrate the freezer.
B. Accurate leveling is necessary for correct drainage
of freezer barrel and to insure correct overrun. Place
a spirit level on top of the freezer at each corner to
check for level condition. If adjustment is necessary,
level the freezer by turning the bottom part of each
leg in or out. Then separate freezer base gasket and
install with the seam to the back and the flat to the
bottom. (Fig.4).
Fig. 4. Space and Ventilation Requirements
C. Air cooled freezers require correct ventilation. The
right side of the freezer is the air intake and must
have a 3" (7.5cm) clearance. Air discharges out of
the left side of the unit and must have 3" (7.5cm)
clearance. Do not obstruct the intake or discharge
(Fig.4).
FAILURE
TO
VENTILATION WILL VOID WARRANTY!
D. Place the OFF-ON switch in the OFF position.
E. Install the drip tray, drain trays, covers and other
miscellaneous parts on the freezer. (Fig. 5)
Figure 5. Installing Tray and Insert
F. Connect the power cord. The plug is designed for
208 or 230 volt/20 amp duty. Check the nameplate
on your freezer for proper supply. The unit must be
connected to a properly grounded receptacle. The
electrical cord furnished as part of the freezer has a
three prong grounding type plug (Fig. 6). The use of
an extension cord is not recommended. If one must
be used, use one with a wire size 12 gauge or heavier
with a ground wire. Do not use an adaptor to get
around grounding requirement.
DO NOT ALTER OR DEFORM PLUG IN ANY
WAY!
Figure 6. Power Cord
4
CAUTION
PROVIDE
ADEQUATE
CAUTION